Mx2 Inverter Specifications; Model-Specific Tables For 200 V And 400 V Class Inverters - Omron 3G3MX2 User Manual

Mx2 series 200 v class three-phase input 0.1 to 15 kw 200 v class single-phase input 0.1 to 2.2 kw 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

MX2 Inverter Specifications

1-2
MX2 Inverter Specifications
1-2-1

Model-specific tables for 200 V and 400 V class inverters

Item
3G3MX2 inverters, 200 V models AB001
Applica-
kW
VT
ble motor
CT
size *2
HP
VT
CT
Rated
200 V
VT
capacity
CT
(kVA)
240 V
VT
CT
Loss at 100% load
W
Efficiency at rated load %
Rated input voltage
Rated output voltage *3
Rated output current
VT
(A)
CT
Starting torque *6
Braking
Without resistor
With resistor
DC braking
Weight
kg
lb
Note 1
Note 2
Note 3
Note 4
Note 5
Note 6
The following tables are specific to MX2 inverters for the 200 V and 400 V
class model groups. Note that General Specifications on page 7 in this chap-
ter apply to both voltage class groups. Footnotes for all specification tables fol-
low the table below.
Single-phase 200 V class Specifications
AB002
0.2
0.4
0.1
0.2
1/4
1/2
1/8
1/4
0.4
0.6
0.2
0.5
0.4
0.7
0.3
0.6
12
22
89.5
90
Single-phase: 200 V-15% to 240 V+10%, 50/60 Hz±5%
3-phase: 200 to 240 V (proportional to input voltage)
1.2
1.9
1.0
1.6
200% at 0.5 Hz
100%: 50 Hz
50%: 60 Hz
150%
Variable operating frequency, time, and braking force
1.0
1.0
2.2
2.2
Footnotes for the preceding table and the tables that follow:
The protection method conforms to JEM 1030.
The applicable motor refers to a standard 3-phase motor (4p). When using
other motors, care must be taken to prevent the rated motor current
60 Hz) from exceeding the rated output current of the inverter.
The output voltage decreases as the main supply voltage decreases (except
when using the AVR function). In any case, the output voltage cannot exceed
the input power supply voltage.
To operate the motor beyond 50/60 Hz, consult the motor manufacturer for the
maximum allowable rotation speed.
For achieving approved input voltage rating categories:
• 460 to 480 VAC - Over-voltage category 2
• 380 to 460 VAC - Over-voltage category 3
To meet the Over-voltage category 3, insert an EN or IEC standard compliant
isolation transformer that is earth grounded and star connected (for Low
Voltage Directive).
At the rated voltage when using a standard 3-phase, 4-pole motor.
AB004F
AB007
0.55
1.1
0.4
0.75
3/4
1.5
1/2
1
1.2
2.0
1.0
1.7
1.4
2.4
1.2
2.0
30
48
93
94
3.5
6.0
3.0
5.0
1.1
1.4
2.4
3.1
Section 1-2
AB015
AB022
2.2
3.0
1.5
2.2
3
4
2
3
3.3
4.1
2.7
3.8
3.9
4.9
3.3
4.5
79
104
95
95.5
9.6
12.0
8.0
11.0
70%: 50 Hz
20%: 50 Hz
50%: 60 Hz
20%: 60 Hz
100%
1.8
1.8
4.0
4.0
(50/
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents