7.2.
The "tare" is used to cancel the mass of a container, which is placed on the pan to
contain the article to be weighed.
Caution
The tare reduces the weighing range.
The current tare value is reset by pressing the
off. (Reset value is zero.)
The storable preset tare value must be within the minimum weighing range for
the HV-G series.

7.2.1. Tare Input by Weighing

Step 1 Place the container on the pan.
Step 2 Wait for the stability mark to be displayed. Press the
becomes zero and the net mark is displayed.
Step 3 Place an article to be weighed into the container. Wait for the stability mark to be
displayed and read its net display.
Step 4 Remove the article and the container from the pan.

7.2.2. Digital Input (Preset Tare)

Step 1 Press and hold the
Then the blank or stored tare value is displayed. The blank display means that the
tare value is zero (reset value). And
Step 2 Set the preset tare value using the following keys.
key
key
Step 3 Press the
Then the scale displays the net value (the gross weight value minus the tare value).
Step 4 Place an article to be weighed into the container. Wait for the stability mark to be
displayed and read its net display.
Step 5 Remove the article and the container from the pan.
HV-G/HW-G Series

Tare (And Net Display)

key and press the
SET
Selecting the figure to be changed.
Changing the number of the figure.
key to store the new preset tare value.
ENTER
ZERO
key.
TARE
or
blinks.
Page 25
key or turning the scale
key. The display
TARE
7. Basic Operation