A&D HW-10KGL Instruction Manual page 56

Hv-g/hw-g series digital platform scale
Hide thumbs Also See for HW-10KGL:
Table of Contents

Advertisement

Item
Display
Accumulation
function
f8 4
f8 5
f9 0 #
f9 1
f9 2
Print mode
f9 3
f9 4
f9 5
f10 0 #
f10 1
Full/Dribble
batch
sub-func-ti
f10 2
on
f10 3
f11 00 #
Address
f11 01
to
f11 99
"#": factory settings. The "nearly-zero" is within ±5 digits from zero point in the unit of kg.
15. The Function Table
When the display is a stable value and not nearly-zero, the scale
accumulates the data automatically. The next accumulation can
be performed after the display becomes nearly-zero.
Use
Recording the number and mass of articles removed
from the pan. (Place the articles on the pan. Press the
key at each removal.)
TARE
At each end of the full/dribble batch function, the scale
accumulates the data automatically.
Use
Packaging articles like a powder, it is used for recording
the bag number and total mass.
Selects the printing condition. Option OP-06 for type V is
required.
No print.
Press the
key to output the data.
PRINT
Auto-print +
When the display becomes a positive stable value and not
nearly-zero, the scale outputs the data automatically. Next
output can be performed after the display becomes
nearly-zero or negative value.
Auto-print +/-
When the display becomes a stable value and not
nearly-zero, the scale outputs the data automatically. Next
output can be performed after the display becomes
nearly-zero.
At each end of full/dribble batch function, the data is output.
When the accumulation function is used, the data is output.
Selects the details of the full/dribble batch function (f6 9)
When the
key is pressed after final value is reached, the
F
current process is finished.
When the stability mark is displayed after final value is reached,
the current process is finished automatically.
When the
key is pressed, the scale automatically tares and
SET
starts the full/dribble batch process. When the
after final value is reached, the current process is finished
When the
key is pressed, the scale automatically tares and
SET
starts the full/dribble batch process. When the stability mark is
displayed after final value is reached, the current process is
finished.
Select the address for RS-422 / RS-485 for option OP-04
Use
Addresses from 01 to 99 are available. Scales are
assigned unique addresses and are controlled by the
computer.
(RS-232C should be set to "00".)
Page 54
Description
key is pressed
F
HV-G/HW-G Series
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

Hide quick links:

Advertisement

Table of Contents
loading