Operation And Performance (Examples) - A&D HW-10KGL Instruction Manual

Hv-g/hw-g series digital platform scale
Hide thumbs Also See for HW-10KGL:
Table of Contents

Advertisement

11.2. Operation and Performance (Examples)

Example 1
This example is set as follows:
Function table
Upper limit value (HI)
Lower limit value (LO)
Case
The comparison starts when the scale is turned on.
When the current value is less than 6.500kg, LO is displayed.
When the current value is between 6.500kg and 7.000kg, OK is displayed.
When the current value is greater than 7.000kg, HI is displayed.
Example 2
This example is set as follows:
Function table
Upper limit value (HI)
Lower limit value (LO)
Case
The comparison starts when the
displayed.
When the current value is less than -1.000kg, LO is displayed.
When the current value is between -1.000kg and 2.000kg, OK is displayed.
When the current value is greater than 2.000kg, HI is displayed.
HV-G/HW-G Series
(The scale always compares the weight value
f6 1
even when the value is nearly-zero.)
7.000 kg
6.500 kg
(When the
f6 4
mark is displayed, the scale compares the
current weight value with the upper limit value
and the lower limit value immediately.)
2.000 kg
-1.000 kg
key is pressed and the stability mark is
SET
Page 39
key is pressed and the stability
SET
11. Upper/Lower Comparator Function

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents