Options; Prtdiag Command - Fujitsu SPARC ENTERPRISE M9000 Service Manual

Fujitsu server user manual
Hide thumbs Also See for SPARC ENTERPRISE M9000:
Table of Contents

Advertisement

The following example shows output for one iostat command.
# iostat -En
c0t0d0
Model: ST3120026A
Size: 120.03GB <120031641600 bytes>
Media Error: 0 Device Not Ready: 0
Illegal Request: 0
c0t2d0
Vendor: LITE-ON
No:
Size: 0.00GB <0 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
2.9.2

prtdiag Command

The prtdiag command displays configuration and diagnostic information. The
diagnostic information identifies any failed component.
The prtdiag command is located in the
/usr/platform/platform-name/sbin/ directory.
Note – The prtdiag command might indicate a slot number different than that
identified elsewhere in this document. This is normal.
2.9.2.1

Options

TABLE 2-14
help troubleshooting.
Options for prtdiag
TABLE 2-14
Option
Description
No option
Lists components.
Verbose mode.
-v
Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Revision: 8.01
Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Product: COMBO SOHC-4832K Revision: O3K1 Serial
describes options for the prtdiag command and how those options can
How It Can Help
Identifies CPU information, memory configuration,
mounted PCI cards, OBP version number, mode switch
status, and CPU operational mode.
Provides the same information as "no option." Additionally,
lists the detail information of PCI cards.
Serial No: 3JT4H4C2
No Device: 0 Recoverable: 0
Chapter 2
Product Overview and Troubleshooting
2-39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m8000

Table of Contents