Fujitsu SPARC ENTERPRISE M9000 Service Manual page 296

Fujitsu server user manual
Hide thumbs Also See for SPARC ENTERPRISE M9000:
Table of Contents

Advertisement

2. From the OS, execute the cfgadm -a command to verify the Ap_Id of the PCI
card.
Example: If the PCI card in PCI slot 3 of IOU#0 is replaced
# cfgadm -a
Ap_Id
iou#0_pci#3
The AP_Id (iou#0_pci#3) verified here is referred to as PCI_ApId, and the
subsequent explanations of cfgadm operations for the PCI card use the term
PCI_ApId.
3. From the OS, execute the cfgadm -c unconfigure <PCI_ApId> command to
unconfigure the replacement target PCI card from the driver.
# cfgadm -c unconfigure iou#0_pci#3
4. From the OS, execute the cfgadm -c disconnect <PCI_ApId> command to
stop supplying power to the replacement target PCI card.
# cfgadm -c disconnect iou#0_pci#3
5. From the OS, execute the cfgadm -a command to confirm that the status of the
PCI card has changed from "configured" to "unconfigured," and from
"connected" to "disconnected."
# cfgadm -a
Ap_Id
iou#0_PCI#3
6. Blink the ATTENTION LED (amber) of the PCI card to be replaced.
# cfgadm -x led=attn, mode=blink iou#0_pci#3
7. Connect the clip of the antistatic wrist strap and of the antistatic mat to the
server grounding port. See
13-4
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
Type
Receptacle
:
pci_pci/hp
connected
Type
Receptacle Occupant Condition
:
unknown
disconnected
Section 1.4, "Antistatic Precautions" on page
Occupant
Condition
configured
ok
unconfigured
unknown
1-6.