Fujitsu SPARC ENTERPRISE M9000 Service Manual page 274

Fujitsu server user manual
Hide thumbs Also See for SPARC ENTERPRISE M9000:
Table of Contents

Advertisement

3. Use the maintenance menu to select the XSCFU to be replaced. (The
maintenance menu is used up to
The fieldeng permission is required for executing this command.
a. From the console that is connected to the Active XSCF, log in to the XSCF,
FIGURE 11-4
---------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. CMU/IOU(CPU Memory Board Unit/IO Unit)
2. FAN(Fan Unit)
3. PSU(Power Supply Unit)
4. XSCFU(Extended System Control Facility Unit)
5. DDC_A(DDC for BP_A)
---------------------------------------------------
Select [1-5|c:cancel] :
Note – DDC_A is displayed only for the M8000
b. From the replacement parts list on the maintenance menu, select 4, "XSCFU."
c. From here, perform the operation according to the guidance displayed in the
4. Connect the clip of the antistatic wrist strap and of the antistatic mat to the
server grounding port. See
11-6
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
and execute the replacefru command.
As shown in
FIGURE 11-4
Initial Page of the Maintenance Menu
maintenance menu.
Check the states of LEDs (POWER LED: off; CHECK LED: blinking) on the
XSCFU to be replaced, and begin the actual replacement work when a message
instructing the user to replace the target XSCFU is displayed. Leave the
maintenance menu as is until
Step
10.)
, the initial page of the maintenance menu is displayed.
Step
6.
Section 1.4, "Antistatic Precautions" on page
1-6.