Fmadm Faulty Command; Fmadm Repair Command - Fujitsu SPARC ENTERPRISE M9000 Service Manual

Fujitsu server user manual
Hide thumbs Also See for SPARC ENTERPRISE M9000:
Table of Contents

Advertisement

# fmadm config
MODULE
cpumem-diagnosis
cpumem-retire
eft
fmd-self-diagnosis
io-retire
syslog-msgs
2.8.3.2

fmadm faulty Command

The fmadm faulty command can be used mainly to identify the status of faulty
components.
In the following example, the PCI card is degraded and associated with the
following UUID 49847040-ce57-e453-9adc-fe66c7c65384. Also, the "faulted"
state may be displayed.
# fmadm faulty
STATE
-----
degraded
Note – The error information remains in the Solaris OS even when replacement of
the faulty component is completed. Identify the UUID by executing the fmadm
faulty command, and reset the error information by executing the fmadm repair
command with the UUID specified.
2.8.3.3

fmadm repair Command

The fmadm repair command can be used to reset the error information for a faulty
component in the Solaris OS.
# fmadm repair 49847040-ce57-e453-9adc-fe66c7c65384
fmadm: recorded repair to 3de29de5-6332-ec64-9b49-bacc739fe3c3
2-36
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
VERSION
STATUS
DESCRIPTION
1.5
active
UltraSPARC-III/IV CPU/Memory Diagnosis
1.0
active
CPU/Memory Retire Agent
1.13
active
eft diagnosis engine
1.0
active
Fault Manager Self-Diagnosis
1.0
active
I/O Retire Agent
1.0
active
Syslog Messaging Agent
RESOURCE / UUID
--------------------------------------------------
dev:////pci@2,600000
49847040-ce57-e453-9adc-fe66c7c65384

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m8000

Table of Contents