5. Switch off all main line switches for the AC section (ACS) in the power supply
system.
For details, see
Note – If the optional three-phase 200 VAC input power supply unit is installed, the
main line switches are located on the three-phase ACS.
Caution – If the dual power feed option is installed, switch off the main line
switches for both power supply units.
Caution – After stopping all the domains, be sure to switch off the main line
switches in the power supply system to completely shut off the supply of power.
6. Connect the clip of the antistatic wrist strap and of the antistatic mat to the
server grounding port. See
7. Ensure that the metallic underside of the wrist strap is in direct contact with
your skin. The wrist strap should be snug around the wrist so that it does not
rotate. See
Caution – Before handling FRUs, be sure to connect the clip of the antistatic wrist
strap and of the antistatic mat to the server grounding port, and attach the band of
the wrist strap to one of your wrists. Place the FRUs on the grounded antistatic mat.
Failure to take these antistatic measures might result in serious damage.
8. Remove the DDC to be replaced. (See
a. Using a Phillips screwdriver, turn the knob screw securing the bottom
b. Unlock the eject/lock levers to pull the DDC off the backplane.
c. While grasping the eject/lock levers, pull out the DDC slowly from the slot.
9. Place the removed DDC on an antistatic mat.
10. Mount the replacement DDC by following the removal instructions in
reverse order. Align the DDC with the slot guides, insert it carefully, and secure
it firmly.
Push the eject/lock levers as far as they will go, and then push the knob screws
on the right and left eject/lock levers to lock them in position. If the knob screws
remain in position, the DDC is securely mounted.
19-8
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
Section 4.5.3, "Main Line Switch Locations" on page
Section 1.4, "Antistatic Precautions" on page
eject/lock lever 90 to 180 degrees to unlock the lever. (Turn the knob screw
while lightly pulling the lever with one hand.)