Fujitsu SPARC ENTERPRISE M9000 Service Manual page 164

Fujitsu server user manual
Hide thumbs Also See for SPARC ENTERPRISE M9000:
Table of Contents

Advertisement

4. Collect an XSCF snapshot to archive system status prior to upgrade.
This will be help in case any problem occurred in this procedure.
XSCF> snapshot -t user@host:directory
5. Update the XCP version.
For the firmware updating procedures, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User's Guide.
6. After updating the XCP, reset the XSCF.
XSCF> rebootxscf
7. After resetting the XSCF, log in to the XSCF again.
8. Mount the CPU module (CPUM) on the CMU for add-on.
For the procedure, see the description about the CPU module installation in
Section 6.5.1, "Replacing a CPU Module" on page
9. Mount the CMU, described in
a. Executing the addfru(8) command and select "CMU/IOU" from the
XSCF> addfru
b. Perform the operation according to the instructions displayed in the
Note – Do not fail to execute the diagnosis of newly mounted CMU in the
maintenance menu of addfru(8) command.
10. Confirm that the mounted CPU module has been recognized by the server, and
the error indicator asterisk (*) is not displayed.
XSCF> showhardconf -M
11. Confirm no abnormality occurred by using showlogs error -v and
showstatus(8) commands.
XSCF> showlogs error -v
XSCF> showstatus
12. Move the key position on the operator panel from Service to Locked.
6-6
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
maintenance menu.
maintenance menu, referring to
Replacement" on page
Step
8, on the server.
Section 6.3, "Active Replacement and Hot
6-12.
6-30.