Cold Addition - Fujitsu SPARC ENTERPRISE M9000 Service Manual

Fujitsu server user manual
Hide thumbs Also See for SPARC ENTERPRISE M9000:
Table of Contents

Advertisement

FIGURE 25-1
---------------------------------------------------
Maintenance/Addition Menu
Please select a type of FRU to be added.
1. CMU/IOU
2. FAN
3. PSU
---------------------------------------------------
Select [1-3|c:cancel]:
Note – DDC_A is displayed only for the M8000.
Perform the operation according to the instructions displayed in the addition
menu.
Note – In hot addition of an IOU, mount the CMU and IOU in the proper location.
Otherwise, the added IOU may not operate.
25.1.2

Cold Addition

In cold addition the main line switches of the system are turned off and the addition
menu is not available. Perform the addition according to the following procedure.
1. Set the mode switch on the operator panel to Service.
2. Turn off power of all domains together.
Press and hold the POWER switch on the operator panel for at least four seconds
or execute the poweroff -a command from XSCF.
3. Switch off all main line switches for the AC section (ACS) in the power supply
system.
Initial Page of the Maintenance Menu
(CPU Memory Board Unit/IO Unit)
(Fan Unit)
(Power Supply Unit)
Chapter 25
Addition and Deletion of CMU, DIMM, IOU, HDD, PCI Cards and TAPEU
25-3