3. Switch off all main line switches for the AC section (ACS) in the power supply
system.
4. Delete the FRUs.
The procedures are the same for removing of the replacement for the appropriate
FRU. Some steps for deleting a FRU are the same as for replacing a FRU. For more
details about the deletion procedure, refer to the appropriate chapter on FRU
replacement.
Caution – For deletion, a filler panel (
slot. Without filler panels, the system might overheat.
5. Switch on all main line switches for the AC section (ACS) in the power supply
system.
6. Confirm that the XSCF STANDBY LED (green) on the operator panel remains
lit. If it is blinking, wait until it remains lit.
7. Start (turn on power to) all domains together using one of these steps:
8. Confirm configuration information of the system by using the showhardconf
command of XSCF.
XSCF> showhardconf
If the deleted FRU is not displayed, it is operating normally.
Note – The showhardconf command cannot check the PCI card, Hard Disk Drive,
and tape drive unit. To check the Hard Disk Drive and tape drive unit, use the
probe-scsi-all command from the ok prompt. To check the PCI card, use the
show-devs command from the ok prompt.
9. When CMUs or IOUs are deleted, cancel the SB settings and domain settings
for each CMU and IOU.
Ask a system administrator or a domain administrator for assistance.
10. Set the mode switch on the operator panel to Locked.
25-6
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
Press and hold down (for less than four seconds) the POWER switch on the
operator panel.
Execute the poweron -a command from XSCF.
) must be installed in the empty