Configuring A Pci Card; Confirming The Hardware - Fujitsu SPARC ENTERPRISE M9000 Service Manual

Fujitsu server user manual
Hide thumbs Also See for SPARC ENTERPRISE M9000:
Table of Contents

Advertisement

1. Configuring into a domain
To configure CMU or IOU into the domain, enter the following command from
the terminal that is connected to the XSCF:
XSCF> addboard -c configure
The system administrator permission is required for executing this command.
2. Checking resources
Log in to the XSCF and execute the showboard command to verify that the target
CMU or IOU has been correctly configured.
4.2.3.2

Configuring a PCI card

1. From the Solaris OS, use the cfgadm command to configure and connect the
component to the domain:
# cfgadm -c configure AP_ID
where AP_ID is the IOU and PCI card as shown in the output of cfgadm.
2. Use the cfgadm command to confirm the component is now connected and
configured:
# cfgadm
AP_ID
..
iou#0-pci#1
iou#0-pci#2
iou#0-pci#3
iou#0-pci#4
4.2.4

Confirming the Hardware

1. Confirm that the replacement components are normal by using the
showhardconf or showstatus command of XSCF.
Unless "*" is displayed for a replacement CMU, CPU, or DIMM, it is operating
normally.
-d 0 00-0
Type
Receptacle
unknown
empty
unknown
empty
etherne/hp
connected
fibre/hp
connected
Occupant
Condition
unconfigured
unknown
unconfigured
unknown
configured
ok
configured
ok
Chapter 4
FRU Removal Preparation
4-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m8000

Table of Contents