19. Confirm switching over between XSCFs works properly.
XSCF> switchscf -t Standby
The XSCF unit switch between the Active and Standby states.
Continue? [y|n] :y
a. When the READY LED on XSCFU_B#1 remains lit, log in to XSCFU#0 using
a serial connection or LAN connection.
b. Confirm switching over between XSCFs using the following commands:
XSCF> showhardconf
Confirm XSCFU#1 is now the standby, and that XSCFU#0 has become the active.
XSCF> showlogs error
Confirm no new errors have been recorded since the check in
XSCF> showlogs event
Confirm a message "XSCFU entered active state from standby state".
XSCF> showstatus
Confirm a message "No failures found in System Initialization".
20. Power on all domains.
XSCF> poweron -a
21. Log in to XSCFU#0 and confirm all domains start up properly.
XSCF> showlogs power
22. Check that there are no new errors.
XSCF> showlogs error
In case an abnormality is encountered, take appropriate maintenance action and
contact service engineer.