11. Mount the replacement PCI card on the PCI cassette. (Perform this work on the
conductive mat.)
FIGURE 13-6
Card positioning post and card positioning tab
FIGURE 13-6
TABLE 13-2
Item
1
2
The post (item 1 in
If the post is not properly seated in the notch, the mounting bracket of the card may
be bent and the card may end up being affixed in an inclined position on the PCI
cassette. If a card is affixed in an inclined position, it will not be in proper electric
contact with the socket on the IOU.
The tab (item 2 in
This tab is helpful in positioning the card when it is mounted on the PCI cassette
(however, some types of cards do not have the notch).
13-10
SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
shows card positioning post and card positioning tab.
1
2
Card positioning post and card positioning tab
Description
Card positioning post
Card positioning tab
) is seated in the notch of the bracket of the PCI card.
FIGURE 13-6
) fits in the notch on the lower part of the PCI card.
FIGURE 13-6