Active Replacement - Fujitsu SPARC ENTERPRISE M9000 Service Manual

Fujitsu server user manual
Hide thumbs Also See for SPARC ENTERPRISE M9000:
Table of Contents

Advertisement

TABLE 13-1
TABLE 13-1
Slot name
PCI slot
For the following devices, replacement procedures have the same steps except that
LEDs to be checked, eject levers, and names used for status display are different.
PCI cassette (PCICS)
PCI card
IOU onboard device card (IOUA)
Link card
Note – The steps of the replacement procedures for I/O boxes and link cards
mounted in external I/O expansion units, PCI cards, I/O boards, and power supply
units are basically the same as those described in this manual. For details, see the
External I/O Expansion Unit Installation and Service Manual.
The following explains the replacement procedure for a PCI card, which is a typical
example.
13.2

Active Replacement

The PHP function enables active replacement of PCI cassettes (PCICSs) and link
card. Active replacement cannot be performed for IOU onboard device cards
(IOUAs).
The active replacement procedure is as follows.
1. Unlock and open the appropriate door on the server.
For details, see
Caution – Before touching FRU or the dummy (filler) unit, see
"Antistatic Precautions" on page 1-6
Failure to do so might result in serious damage to operating domains.
shows abbreviated name and numbers of PCI slots in an IOU.
Abbreviated Name and Numbers of PCI Slots
Chapter
5.
Abbreviated name and numbers
PCI#0 to 7
and be sure to wear the antistatic wrist strap.
Chapter 13
PCI Slot Device Replacement
Section 1.4,
13-3