2.5.2.2

Checking the Firmware Configuration

Login authority is required to check the firmware configuration. The following
procedure for these checks can be made from the maintenance terminal:.
1. Log in to the XSCF.
2. Execute the version command.
XSCF> version
The version command will print the firmware version information to the screen.
See the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User's
Guide for more detailed information.
2.5.3

Downloading the Error Log Information

If you want to download the error log information, use the XSCF log fetch function.
The XSCF Unit has an interface with external units so that a service engineer can
easily obtain useful maintenance information such as error logs
Connect the maintenance terminal, and use the CLI or BUI to issue a download
instruction to the maintenance terminal to download Error Log information over the
XSCF-LAN.
Note – When the XSCF unit has a redundant configuration, log in also to the
standby XSCF and obtain the log file in the same manner.
2.6

Error Conditions

This section describes error conditions and relevant corrective actions.
This work is explained in the following sections:
Section 2.6.1, "Predictive Self-Healing Tools" on page 2-27
Section 2.6.2, "Monitoring Output" on page 2-28
Section 2.6.3, "Messaging Output" on page 2-29
Details of the fault information, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User's Guide.