EPSON EPL-N4000/EPL-N4000+
Figure 7-21. Duplex PWB
Rev.B
MCU PWB
Table 7-19. Signal Name
Signal Name
OPT$TX+
Status of Duplex Module sent to MCU. High=Mark.
Low=No mark
OPT#RX+
Status of MCU sent to the Duplex Module. High=Mark.
Low=No mark
DUP#DET
Monitors presence of a Duplex Module. High=Duplex
Module installed. Low=Duplex Module not installed
DREGI
Monitors paper at the Registration Sensor. High=Paper
present. Low=Paper not present
INV SW
Monitors paper at the Fuser Exit Sensor. High=Paper
present. Low=Paper not present
CL$ICW
Switches the Inverter CW Clutch. High=Off. Low=On
CL$ICCW
Switches the Inverter CCW Clutch. High=Off. Low=On
INTLK#DUP
Monitors the Duplex Cover Interlock Switch. High=Cover
open. Low=Cover closed.
SNR#DEXIT
Monitors paper at the Duplex Exit Sensor. High=Paper
present. Low=Paper not present
SNR#DWAIT
Monitors paper at the Duplex Wait Sensor. High=Paper
present. Low=Paper not present
SOL$DGATE
Switches the Duplex Exit Gate Solenoid. High=Off.
Low=On
/A, A, /B, B
Pulse signals sent by the Duplex PWB to rotate the
Duplex Motor
Chapter 7
Appendix