Figure 7-14. Toner Sensor
Table 7-12. Signal Name
Signal Name
CRUM$PWR
Switches CRUM power.
CRU$CLK
Clock signal for CRU Memory
CRU$DATA
CRU Memory data
TNR#EMP
Monitor toner quantity in the ET Cartridge. Low=Quantity
is low. Hiigh=Enough quantity.
Rev.B
Xerographic CRU
MCU PWB
Description
Figure 7-15. HVPS M CU PWB
Table 7-13. Signal Name
Signal Name
BTR#MON
Monitors BTR current level
BTR$SEL
Switches BTR voltage. High=Positive voltage.
Low=Negative voltage
BTR$RMT
Controls the current value to the BTR
DTS$ON
Switches Detack Saw and Chute Bias voltage. High=Off.
Low=On
BCRAC$CLK
Controls the AC voltage value to the BCR. Negative logic
BCRDC$ON
Switches BCR voltage. High=Off. Low=On
DBAC$CLK
Controls the AC voltage value to the Magnet Roll.
Negative logic
DB$ON
Switches DB voltage. Negative logic
Chapter 7
Appendix
Description
243