Clearance (mm)
2.6
4.0
4.0
For a host or other expansion card fitted in the host, using or generating
voltages greater than 300V (rms or dc), advice from a competent safety
engineer must be obtained before installation of the relevant equipment.
Any other usage will INVALIDATE the approval of the apparatus, if as a
result, it then ceases to conform to the standards against which approval
was granted.
Approved Hardware
1.
Host computer, with an earthing terminal, which is "CE" marked to
include compliance to LVD and EMC European Directives.
2.
Computer chassis will comprise the following as minimum:
a. Pentium II PC, 5 expansion slots, SVGA, IDE, 4.0 GB, keyboard
b. Color monitor, non-interlaced, 1024 x 768
c. Mouse, two button
d. Memory, at least 128 MB RAM
e. CD ROM
f. Modem 28,800 baud, approved by BABT (optional)
3.
AltiGen Quantum cards, Rev. D:
ALTI-CD0804UD, ALTI-CD0408UD, ALTI-CD0012UD, ALTI-
DID0408UD
4.
AltiGen Triton cards:
ALTI-TTAS-12, ALTI-T1E1, ALTI-TTRS-12, ALTI-TTAT-
12GS, ALTI-TTAT-12, ALTI-TTIP-4, ALTI-TTIP-8
Operating Software
Provided by AltiGen: Product name OE Rev. 4.5 or above.
AltiWare OE System Installation & Administration Manual
Creepage (mm)
3.0 (4.8)
5.0 (8.0)
6.4 (10.0)
Liability & Warranty
Voltage used or
generated by host or
other cards
Up to 125 Vrms or Vdc
Up to 250 Vrms or Vdc
Up to 300 Vrms or Vdc
xxi