Cisco III - Supervisor Engine III Message Manual page 53

Cisco ios system message guide
Table of Contents

Advertisement

Chapter 2
Messages and Recovery Procedures
Error Message %C6KENV-4-MINORTEMPOKALARMRECOVER: [chars]. It has returned to normal
operating status.
Explanation
Recommended Action
Error Message %C6KENV-4-MINORTEMPSUPOKALARM: All temperature sensors of Supervisor
in slot [dec] have failed. If the temperature sensor does not recover by itself,
please power cycle the chassis when it is feasible
Explanation
Recommended Action
possible.
Error Message %C6KENV-4-MINORTEMPSUPOKALARMRECOVER: Supervisor in slot [dec] has
returned to normal operating status.
Explanation
Recommended Action
Error Message %C6KENV-4-MINORVTTOKALARM: All the backplane vtt temperature sensor
have failed. If the backplane vtt temperature sensor does not recover by itself,
please power cycle the chasis when it is feasible
Explanation
Recommended Action
chassis when possible.
Error Message %C6KENV-4-MINORVTTOKALARMRECOVER: Backplane VTT has returned to normal
operating status.
Explanation
Recommended Action
OL-11469-02
All module temperature sensors have returned to normal operating status.
No action is required.
All temperature sensors have failed in the supervisor engine.
If the temperature sensors do not recover, power cycle the chassis when
The supervisor engine temperature sensors have returned to normal operating status.
No action is required.
All backplane VTT temperature sensors have failed.
If the backplane VTT temperature sensors do not recover, power cycle the
The backplane VTT has returned to normal operating status.
No action is required.
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
C6KENV Messages
2-23

Advertisement

Table of Contents
loading