Chapter 2
Messages and Recovery Procedures
WARNING: Any system reset will change the system operating mode which can result
in degradation of system performance. To eliminate this from occurring, remove
Module [dec] DFC or replace with a system compatible DFC.
Error Message %C6KENV-2-FANUPGREQ: Module [dec] not supported without fan upgrade
Error Message %C6KENV-2-SHUTDOWN_NOT_SCHEDULED: Major sensor alarm for [chars] is
ignored, [chars] will not be shutdown.
C6KENV-4
Error Message %C6KENV-4-ALARMCLR: [chars] alarm cleared
Error Message %C6KENV-4-FANCOUNTFAILED: Required number of fan trays is not present
Error Message %C6KENV-4-FANCOUNTOK: Required number of fan trays is present
OL-11469-02
The DFC in the specified slot does not have the same software operating mode as the
Explanation
rest of the system. The DFC will remain powered down and cannot be activated.
Enter the show module and show platform earl-mode commands to view the
Recommended Action
difference between the DFC in the specified slot and the operating mode of the rest of the system.
Explanation
The supervisor engine and the DFC in the specified slot require a fan tray upgrade. A
system shutdown is scheduled.
Recommended Action
Upgrade the system fan tray.
Explanation
The system detected that the specified module should be shut down because it exceeded
major sensor thresholds. However, the command that shuts down the module in the event of a major
sensor alarm has been overridden, so the specified module will not be shut down. The command used
to override the shutdown is no environment-monitor shutdown.
Remove the configuration that bypasses the module shutdown due to sensor
Recommended Action
thresholds being exceeded. Shut down the module after removing the configuration.
The specified alarm condition has been cleared. The shutdown has been cancelled.
Explanation
No action is required.
Recommended Action
The system is missing the number of required fan trays to operate properly. Although
Explanation
this is a minor alarm, system components could overheat and be shut down.
Insert the required fan tray as soon as possible.
Recommended Action
Explanation
The number of required fan trays has been restored.
No action is required.
Recommended Action
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
C6KENV Messages
2-21