Chapter 2
Messages and Recovery Procedures
Error Message %CWAN_RP-4-MODULE_CONFIG_MISSING: configuration missing for slot [int]
CWAN_RP-5
Error Message %CWAN_RP-5-LCLOG_MSG : slot [dec]/[dec]: [chars]
OL-11469-02
Some information is missing regarding the configuration of the module in the specified
Explanation
slot. Any startup configuration for the interfaces will not be applied. If the module in the specified
slot is a FlexWAN, details about the port adapters in the FlexWAN are missing from the
configuration information. This information is missing from the SLOTCACHE ROMMON
variable.
If the module in the slot specified in the error message has not previously been
Recommended Action
inserted, it has no previous configuration; therefore, no action is required. If the configuration for
the specified slot in the startup configuration is suitable for the module in that slot, after the module
has loaded, manually apply the configuration by using one of the following two methods. The
second method requires a system reload.
Enter the copy nvram:startup-config system:running-config command to reapply your saved
configuration, then enter the no shutdown command on all interfaces whose configuration was
rejected, and then enter the copy system:running-config nvram:startup-config command to
save your configuration and the WAN module slot configuration.
Enter the copy command to copy your startup configuration to a temporary location (for
example, copy nvram:startup-config bootflash:tmp-config), then enter the copy
system:running-config nvram:startup-config command to update the WAN module slot
configuration, then enter the copy command to restore the temporary copy of the startup-config
(for example, copy bootflash:tmp-config nvram:startup-config), and then enter the reload
command to reload the system.
After using the second method, you may want to use the delete command to remove the temporary
copy of the startup-config. To prevent this condition from recurring, ensure that the SLOTCACHE
variable is updated whenever modules that require it (FlexWANs, but not OSMs) are moved between
slots in the chassis. The SLOTCACHE variable is updated when the running-config is written to
the startup-config using the copy system:running-config nvram:startup-config command (or the
deprecated write memory equivalent). The two methods of restoring the configuration for the
module shown above ensure that the SLOTCACHE variable is updated.
An error has occurred on a module. The slot and CPU number are indicated after the
Explanation
CWAN_RP-5-LCLOG_MSG text. The error message that appears after the slot number is the
original message from the module.
Follow any instructions provided in the error message text. If no instructions
Recommended Action
are provided, copy the message exactly as it appears on the console or in the system log. Research
and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac.
With some messages, these tools and utilities will supply clarifying information. Search for resolved
software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still
require assistance, open a case with the Technical Assistance Center at
http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support
representative and provide the representative with the information you have gathered. Attach the
following information to your case in nonzipped, plain-text (.txt) format: the output of the show
logging and show tech-support commands and your pertinent troubleshooting logs.
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
CWAN_RP Messages
2-79