Cwanlc_Atm Messages; Cwan_Qinq Messages; Cwan_Qinq-3 - Cisco III - Supervisor Engine III Message Manual

Cisco ios system message guide
Table of Contents

Advertisement

CWANLC_ATM Messages

CWANLC_ATM Messages
This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN ATM module
(CWANLC_ATM) messages.
CWANLC_ATM-3
Error Message %CWANLC_ATM-3-VCCLOSEFAIL: [chars]: Failed to remove VC [dec]/[dec]
cause [int]

CWAN_QINQ Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN QinQ
(CWAN_QINQ) messages.

CWAN_QINQ-3

Error Message %CWAN_QINQ-3-CWAN_QINQ_TRUNK_DATAINCONSISTENCY: QinQ data integrity
check failed for bridge-vlan [int] dot1q [int] using trunk encapsulation dot1q
[int], existing record shows mapping with encapsulation dot1q [int].
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
2-74
information you have gathered. Attach the following information to your case in nonzipped,
plain-text (.txt) format: the output of the show logging and show tech-support commands and your
pertinent troubleshooting logs.
An attempt to remove a virtual circuit on the module failed.
Explanation
Copy the message exactly as it appears on the console or in the system log.
Recommended Action
Research and attempt to resolve the issue using the tools and utilities provided at
http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying
information. Search for resolved software issues using the Bug Toolkit at
http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the
Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or
contact your Cisco technical support representative and provide the representative with the
information you have gathered. Attach the following information to your case in nonzipped,
plain-text (.txt) format: the output of the show logging and show tech-support commands and your
pertinent troubleshooting logs.
A data integrity error related to QinQ was detected while a trunk was being configured
Explanation
for the bridge VLAN that is indicated in the message text. The error will be ignored, and the QinQ
update will proceed normally.
Recommended Action
Enter the show cwan qinq command on the module. Copy the message exactly
as it appears on the console or in the system log. Research and attempt to resolve the issue using the
tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and
utilities will supply clarifying information. Search for resolved software issues using the Bug
Chapter 2