C6KENV Messages
Error Message %C6KENV-4-FANHIOUTPUT: Version [dec] high-output fan-tray is in effect
Explanation
system has updated the cooling capacity for the fan tray.
Recommended Action
Error Message %C6KENV-4-FANLOOUTPUT: Version [dec] low-output fan-tray is in effect
Explanation
has updated the cooling capacity for the fan tray.
Recommended Action
Error Message %C6KENV-4-FANPSINCOMPAT: Fan tray and power supply [dec] are
incompatible
Explanation
Although this is a minor alarm, overcurrent protection on the power supply could start without
further warning.
Recommended Action
Error Message %C6KENV-4-FANVERCHK: Power-supply [dec] inserted is only compatible
with Version [dec] fan-tray. Please make sure fan is low-output fan-tray
Explanation
tray is a low-output tray, no action is required. If the fan tray is actually a high-output (version 2)
fan tray, the specified power supply is not able to support the high-output fan tray.
Recommended Action
fan-tray version 2 command to update the system with the upgrade information. Replace the 1000
W or 1300 W power supply, as these two power supplies are not compatible in this chassis with the
version 2 fan tray.
Error Message %C6KENV-4-INSUFFCOOL: Module [dec] cannot be adequately cooled
Explanation
alarm, system components could overheat and be shut down.
Recommended Action
Error Message %C6KENV-4-MINORTEMPOKALARM: [chars] all temperature sensor have
failed. If the module temperature sensor does not recover by itself, please power
cycle the module when it is feasible
Explanation
Recommended Action
when possible.
Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY
2-22
The system has detected that the fan tray is a high-output (version 2) fan tray. The
No action is required.
The system has detected that the fan tray is a low-output (version 1) fan tray. The system
No action is required.
An upgrade of the power supply is required to sufficiently operate this fan tray.
Upgrade the power supply.
The system has detected that the fan tray is a low-output (version 1) fan tray. If the fan
If the fan tray is a high-output (version 2) fan tray, enter the hw-module
The fan tray cannot adequately cool the specified module. Although this is a minor
Upgrade the system fan tray.
All module temperature sensors have failed.
If the module temperature sensors do not recover, power cycle the module
Chapter 2
Messages and Recovery Procedures
OL-11469-02