Hot-Plug Power Supply

Input specifications
Nominal line voltage
Range input line
Frequency range
Power factor
Input current
Inrush current
Holdup time
General specifications
Full output rating
Minimum load
Ambient temperature range
Operating
Storage
Dielectric voltage withstand
Input to output
Input to ground
Input transient susceptibility
Common and differential mode
(superimposed on AC line)
Table 5-2

Hot-Plug Power Supply Specifications

200 to 240 VAC (100 to 120 VAC)
180 to 270 VAC (90 to 132 VAC)
47 to 63 Hz
0.95
3.8 A max at 200 V (7.6 A max at )100 V
<150 A at 132 VAC (cold start)
20 ms from zero crossing at 240 VAC
20 ms from zero crossing at 120 VAC
To 40°C and 465 m (to 104°F and 5,000 ft)
To 32°C and 929 m (derate linearly)
To 90°F and 10,000 ft (derate linearly)
1.0 A on + 5 V output
1.0 A on +12 V output
0.5 A on +3.3 V output
10° to 40°C (50° to 104°F)
-40° to 65°C (-40° to 149°F)
3000 VAC/min
1500 VAC/min
2500V, 1 µs, damped sinusoid 600 V, 10 µs pulse
20% step change in AC input voltage