Table 3-19
Event Messages
Event Type
AC voltage problem
Power AC overload
Automatic Server Recovery–2
System lockup
Operating System
System crash
Automatic OS shutdown

Rapid Error Recovery

Compaq servers provide rapid recovery services for diagnosing and recovering from errors.
These tools are available for local and remote diagnosis and recovery.
Rapid recovery means fast identification and resolution of complex faults. The Rapid Recovery
Engine and Insight Management Agents notify the system administrator when a failure occurs,
ensuring that the server experiences minimal downtime. You enable these features through the
System Configuration Utility. These integrated server management features are:
I
Automatic Server Recovery-2 (ASR-2)
I
IMLs
I
Server Health Logs (on servers not supporting IMLs)
I
Storage Fault Recovery Tracking
I
Storage Automatic Reconstruction
I
Network Interface Fault Recovery Tracking
continued
Event Message
System AC Power Problem (Power
Supply X).
System AC Power Overload (Power
Supply X).
ASR Lockup Detected: Cause
Blue Screen Trap: Cause [NT]
Kernel Panic: Cause [UNIX]
Abnormal Program Termination: Cause
[NetWare]
Automatic Operating System Shutdown
Initiated Due to Fan Failure
Automatic Operating System Shutdown
Initiated Due to Overheat Condition
Fatal Exception (Number X, Cause)
Diagnostics and Troubleshooting 3-47
Action
Check the input power voltage.
I Change the input power to
220 V.
I Add an additional power
supply, or replace with one able
to supply the present load.
I Reduce the load.
Call the service provider or Compaq
for diagnosis.
Refer to the documentation for the
operating system.
Refer to the documentation for the
operating system.