Event List; Event Messages - Compaq ProLiant 6400R Maintenance And Service Manual

Compaq proliant 6400r servers
Hide thumbs Also See for ProLiant 6400R:
Table of Contents

Advertisement

Event List

The Event List displays the affected components and the associated error messages. Though the
same basic information displays, the format of the list may differ, depending on whether you
view it on the Integrated Management Display, from within Compaq Insight Manager, or from
the Compaq Survey Utility. An example of the format of an event displayed on the Integrated
Management Display is as follows:
**001 of 010**
---caution---
03/19/1997
12:54 PM
FAN INSERTED
Main System
Location:
System Board
Fan ID: 03
**END OF EVENT**

Event Messages

Event Type
Machine Environment
Fan failure
Fan inserted
Fan removed
Fans not redundant
Overheat condition
Main Memory
Correctable error
threshold exceeded
Table 3-19

Event Messages

Event Message
System Fan Failure (Fan X, Location).
System Fan Inserted (Fan X, Location).
System Fan Removed (Fan X, Location).
System Fans Not Redundant.
System Overheating (Zone X, Location).
Corrected Memory Error threshold passed
(Slot X, Memory Module X).
Corrected Memory Error threshold passed
(System Memory).
Corrected Memory Error threshold passed
(Memory Module unknown).
Diagnostics and Troubleshooting 3-45
Action
Replace fan.
None
None
Add fan.
Check fans.
Replace the defective memory
module.
Replace the memory modules one
at a time (if more than one), and
retest the system after each
replacement.
Replace the memory modules one
at a time (if more than one).
continued

Advertisement

Table of Contents
loading

Table of Contents