Table 3-18
ADU Diagnostic Messages
Message
Description
Board not
Array controller configured for use
attached
with array accelerator board, but one
is not attached.
Configuration
ADU detected that nonvolatile RAM
signature is zero
contains a configuration signature of
zero. Old versions of the System
Configuration Utility could cause this.
Configuration
Array accelerator board configured
signature
for a different array controller board.
mismatch
Configuration signature on array
accelerator board does not match the
one stored on the array controller
board.
Controller
Controller communication failure
communication
occurred.
failure occurred
Controller
EISA nonvolatile RAM does not
detected.
contain a configuration for this
NVRAM
controller.
configuration not
present
Controller
Controller firmware is below the
firmware needs
latest recommended version.
upgrading
Controller is
Controller is installed in slot for
located in
special video control signals. If
special "video"
controller is used in this slot, LED
slot
indicators on front panel may not
function properly.
Controller is not
Controller is not configured. If
configured
controller was previously configured
and you change drive locations, there
may be a problem with placement of
the drives. ADU examines each
physical drive and detects drives that
have been moved to a different drive
bay.
Controller
The controller returned an error from
reported POST
its internal POSTs.
error.
Error Code: x
continued
Diagnostics and Troubleshooting 3-35
Recommended Action
Attach array accelerator board to array
controller.
Run the latest version of System Configuration
Utility to configure the controller and nonvolatile
RAM.
To recognize the array accelerator board, run
the ACU.
ADU was unable to successfully issue
commands to the controller in this slot.
Run the System Configuration Utility to
configure the nonvolatile RAM.
Run Options ROMPaq to upgrade the controller
to the latest firmware revision.
Install the controller In a different slot and run
the System Configuration Utility to configure the
controller and nonvolatile RAM. Then run the
ACU to the configure controller.
Look for messages indicating which drives have
been moved. If none appear and drive swapping
did not occur, run the ACU to configure the
controller and run the System Configuration
Utility to configure nonvolatile RAM. Do not run
either utility if you believe drive swapping has
occurred.
Replace the controller.