Compaq ProLiant 6400R Maintenance And Service Manual page 86

Compaq proliant 6400r servers
Hide thumbs Also See for ProLiant 6400R:
Table of Contents

Advertisement

Table 3-2
POST Error Messages
continued
Error Code
1790-Disk 0
Configuration Error
1791-Disk 1 Error
1792-Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will
automatically be
written to drive array.
1793-Drive Array -
Array Accelerator
Battery Depleted -
Data Lost
(Error message 1794
also displays.)
1794-Drive Array -
Array Accelerator
Battery Charge Low.
Array Accelerator is
temporarily disabled.
Array Accelerator will
be re-enabled when
battery reaches full
charge.
1795-Drive Array -
Array Accelerator
Configuration Error.
Data does not
correspond to this
drive array. Array
Accelerator is
temporarily disabled.
1796-Drive Array -
Array Accelerator Not
Responding.
Array Accelerator is
temporarily disabled.
Audible Beeps
Probable Source of Problem
None
Hard drive error or wrong drive
type
None
Hard drive error or wrong drive
type
None
While the system was in use,
power was interrupted while data
were in the array accelerator
memory. Power was then
restored within 8 to 10 days, and
the data in the array accelerator
were flushed to the drive array.
None
While the system was in use,
power was interrupted while data
were in the array accelerator
memory. Array accelerator
batteries failed. Power was not
restored within 8 to 10 days. The
data in the array accelerator
were lost.
None
The battery charge is below
75%. Posted writes are disabled.
None
While the system was in use,
power was interrupted while data
were in the array accelerator
memory.
The data stored in the array
accelerator do not correspond to
the drive array.
None
Array accelerator is defective or
has been removed.
Diagnostics and Troubleshooting 3-19
Recommended Action
Run the System Configuration
Utility and Diagnostics and
correct.
Run the System Configuration
Utility and Diagnostics and
correct.
No action necessary because no
data were been lost. Perform
orderly system shutdowns to
avoid data remaining in the
array accelerator.
Perform orderly system
shutdowns to avoid data
remaining in the array
accelerator.
Replace the array accelerator
board if batteries do not
recharge within 36 power-on
hours.
Match the array accelerator to
the correct drive array, or run
the System Configuration Utility
to clear the data in the array
accelerator.
Check that the array accelerator
is properly seated.
Run the System Configuration
Utility to reconfigure the
Compaq IDA-2 without the array
accelerator.
continued