3. If the PCI Hot Plug LED is not green, power down the slot by pressing the slot PCI Hot
Plug button or using the PCI Hot Plug utility.
PCI Hot
Plug Button
Amber Green
Figure 2-33. PCI Hot Plug button
4. Wait until both the green and amber LEDs are off.
CAUTION: Never open the slot release lever if the green power LED is on. The PCI Hot Plug
button allows for PCI Hot Plug access directly at each PCI slot. A PCI Hot Plug button is located
above each PCI slot, providing PCI Hot Plug control at the server, eliminating the use of the
PCI Hot Plug utility software. DO NOT open the slot release lever unless the green PCI Hot Plug
LED indicator on the slot is Off. System power down and subsequent data loss could occur.
NOTE: The PCI Hot Plug button allows you to press the button again within 5 seconds to cancel an
action.