From; Features - Compaq ProLiant 6400R Maintenance And Service Manual

Compaq proliant 6400r servers
Hide thumbs Also See for ProLiant 6400R:
Table of Contents

Advertisement

Table 3-18
ADU Diagnostic Messages
Message
Description
Drive (bay) X
An error occurred while ADU tried to
upload code not
read the upload code information
readable
from the drive.
Drive (bay) X
The physical drive was incorrectly
was
replaced after another drive failed.
inadvertently
replaced
Drive Monitoring
ADU unable to get monitor and
features are
performance data because of a fatal
unobtainable
command problem, such as drive
time-out, or unable to get data
because these features are not
supported on the controller.
Drive Monitoring
The monitor and performance
is NOT enabled
features have not been enabled on
for SCSI Port x
this drive.
Drive ID x
Drive time-out
ADU issued a command to a physical
occurred on
drive, but the command was never
physical drive
acknowledged.
bay X
Drive X indicates
Message indicates a physical drive
position Y
that appears to be scrambled or in a
drive bay other than the one for
which it was originally configured.
Duplicate write
Data could not be written to the array
memory error
accelerator board in duplicate
because of the detection of parity
errors. This is not a data-loss
situation.
Error occurred
An error occurred while ADU was
reading RIS copy
tried to read the RIS from the drive.
from SCSI Port x
Drive ID x
FYI: Drive (bay) X
The installed drive was not supplied
is non-Compaq
by Compaq.
supplied
continued
Diagnostics and Troubleshooting 3-37
Recommended Action
If there were multiple errors, the drive may need
to be replaced.
Replace the drive incorrectly replaced, and
replace the original drive that failed. Do not run
the System Configuration Utility and try to
reconfigure. Data will be lost.
Check for other errors (time-outs and so on). If
no other errors occur, upgrade the firmware to a
version that supports monitor and performance,
if desired.
Run the System Configuration Utility to initialize
the monitor and performance features.
The drive or cable may be bad. Check the other
error messages on the Diagnostics screen to
determine resolution.
Examine the graphical drive representation on
ADU to determine proper drive locations.
Remove drive X and place it in drive position Y.
Rearrange the drives according to the ADU
instructions.
Replace the array accelerator board.
If there were multiple errors, the drive may need
to be replaced.
If problems exist with the drive, replace it with a
Compaq drive.
continued