3-14 Compaq ProLiant 6400R Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
1767-Slot x Drive Array Option ROM is Not Programmed Correctly or may Conflict
with the Memory Address Range of an ISA Card. Check the Memory Address
Configuration of installed ISA Card(s) or run Options ROMPaq Utility to attempt
SMART-2/E Option ROM Reprogramming.
1768-Slot x Drive
Array-Resuming
logical drive
expansion process.
1769-Slot x Drive
Array - Drive(s)
disabled due to
failure during
expand. Select F1 to
continue with logical
drives disabled.
Select F2 to accept
data loss and to
re-enable logical
drives.
1771-Primary Disk
Port Address
Assignment Conflict
1772-Secondary
Disk Port Address
Assignment Conflict
1773-Primary Fixed
Disk Port Assignment
Conflict
continued
Audible Beeps
Probable Source of Problem
None
SMART-2 Controller error. A
controller reset or power cycle
occurred during the expansion.
None
SMART-2 Controller error. Data
lost while expanding the array.
The drives have been temporarily
disabled.
None
Internal and external hard drive
controllers are both assigned to
the primary address.
None
Address assignment conflict.
Internal and external hard drive
controllers are both assigned to
the secondary address.
None
Fixed-disk drive error
Recommended Action
Remove or reconfigure
conflicting ISA cards, especially
any not recognized by the
System Configuration Utility.
Reprogramming the ROM on the
SMART-2/E Controller, using the
latest Options ROMPaq
(version 2.29 or later).
No action required.
Press F2 to accept the data loss
and re-enable the logical drives.
Restore data from the backup.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
continued