Compaq ProLiant 6400R Maintenance And Service Manual page 117

Compaq proliant 6400r servers
Hide thumbs Also See for ProLiant 6400R:
Table of Contents

Advertisement

3-50 Compaq ProLiant 6400R Maintenance and Service Guide
When you enable ASR-2 to start Compaq Utilities, the server restarts after a critical error and
loads Compaq Utilities from the system partition on the hard drive.
You can configure the server to start Compaq Utilities in four different ways:
I
Without remote console support, for example, to run Compaq Utilities from the server
console only
I
With remote console support, using modems for dial-in access
I
With remote console support, using a modem to dial a predetermined telephone number
I
With remote console support through a network connection (IP or IPX)
Features
Software error recovery
Software error recovery time-out
Standby recovery server option
Standby recovery server port
Standby recovery time-out
Software error recovery boot option
Thermal shutdown
UPS shutdown
UPS shutdown threshold
Table 3-20
ASR Features
Definition
If enabled, ASR-2 is activated if the OS hangs or has
a crash that results in a lockup.
Determines how long the server waits to enable
ASR-2 after an OS lockup
If enabled, ASR-2 activation initiates a switch to a
standby recovery server.
Port used to communicate with the recovery server.
Determines how long the server waits to initiate
switch after ASR-2 activation.
Enables the server to restart either into the OS or into
Compaq Utilities.
If enabled, shuts down the server if a critical thermal
error occurs.
If enabled, enables the server to perform a shutdown
if a UPS is activated.
Determines how long the server waits to shut down
after the UPS is activated. If desired, the number
should provide enough time for an administrator to
perform any necessary operations or to gracefully
shut down the server.

Advertisement

Table of Contents
loading

Table of Contents