Compaq ProLiant 6400R Maintenance And Service Manual page 83

Compaq proliant 6400r servers
Hide thumbs Also See for ProLiant 6400R:
Table of Contents

Advertisement

3-16 Compaq ProLiant 6400R Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
1782-Disk Controller
Failure
1783-Slot x Drive
Array Controller
Failure
1784-Drive Array
Drive Failure,
Physical Drive
continued
Audible Beeps
Probable Source of Problem
None
Hard disk drive circuitry error
None
ROM installation problem or array
accelerator board problem. If this
message appears immediately
after a ROM installation, the ROM
is defective or not installed
properly.
None
Defective drive and/or cables
Recommended Action
Run Diagnostics. Replace the
failed assembly as indicated.
Check to see if
I The array accelerator board
is attached properly.
I The array controller is firmly
inserted in its slot.
If an error recurs, upgrade the
System ROMs. Otherwise,
replace the Smart Array
Controller.
Check for loose cables. Replace
defective drive X and/or cables.
continued