Compaq ProLiant 6400R Maintenance And Service Manual page 79

Compaq proliant 6400r servers
Hide thumbs Also See for ProLiant 6400R:
Table of Contents

Advertisement

3-12 Compaq ProLiant 6400R Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
1622-Internal SCSI
Jumper Board Not
Installed
1703-SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
1720-Slot x Drive
Array – SMART Drive
Detects Imminent
Failure SCSI: Port y:
SCSI ID x
1724-Slot x Drive
Array – Physical
Drive Position
Change(s) Detected –
Logical drive
configuration has
automatically been
updated
1726-Slot x Drive
Array – Array
Accelerator Memory
Size Change
Detected
1727-Slot x Drive
Array – New Logical
Drive(s) Attachment
Detected. If more
than 32 logical
drives, this message
will be followed by:
Auto-configuration
failed: Too many
logical drives.
1730-Fixed Disk 0
does not support
DMA Mode.
continued
Audible Beeps
Probable Source of Problem
None
The system has detected that the
array enabler board is not
installed.
None
Incorrect cabling
None
Indicated drive has reported a
SMART predictive-failure
condition and may fail later.
None
Logical drive configuration has
been updated automatically after
physical drive position changes.
None
Array accelerator configuration
has been updated automatically
because the replacement of the
array accelerator (or controller)
with one with a different memory
size.
None
Controller has detected an
additional array of drives that
was attached when the power
was off. The logical drive
configuration information has
been updated to add the new
logical drives. The maximum
number of logical drives
supported is 32. Additional
logical drives will not be added to
the configuration.
None
Hard drive error
Recommended Action
Install the array enabler board.
Ensure that the integrated SCSI
controller has the SCSI
termination attached.
If the drive is part of a
nonfault-tolerant configuration,
back up all data before
replacing the drive and restore
all data afterward. If the drive is
part of a fault-tolerant
configuration do not replace it
unless all other drives in the
array are online. Press F1 to
resume.
Press F1 to resume.
Press F1 to resume.
Press F1 to resume.
Run the System Configuration
Utility and correct.
continued

Advertisement

Table of Contents
loading

Table of Contents