Kurzweil K2000 - MUSICIANS GUIDE Musician's Manual page 413

Table of Contents

Advertisement

transpose the layer up an octave, while a pressure level of 64 would leave the pitch
unchanged.
35
Pitch Wheel message (PWheel)
The K2vx is hard-wired to respond to this message. Any parameter with PWheel
assigned as its value will be affected when your MIDI controllerÕs Pitch Wheel is
moved.
36
Bipolar Mod Wheel (Bi-Mwl)
This control source will always respond to MIDI controller 01 (MWheel). Control
source parameters set to this value will generate control signals of -1 when the
MIDI controller 01 message value is 0, and will generate a control signal of +1
when the MIDI controller 01 message is at 127, scaling all values in between. For
example, you might set Src1 on a program layerÕs PITCH page to a value of Bi-
Mwl, and its depth parameter to 1200 cents. Then as long as the ModWhl control
assignment parameter is set to a value of MWheel, your controllerÕs Mod Wheel
will be bipolar; in this case it will bend the layerÕs pitch down as you move the Mod
Wheel toward minimum, and bend the pitch up as you move the Mod Wheel to-
ward maximum.
37
Absolute value of Pitch Wheel (AbsPwl)
This control source always responds to movement of your MIDI controllerÕs Pitch
Wheel, but makes the Pitch Wheel unipolar. Whereas pulling the Pitch Wheel fully
down usually generates a control signal value of -1, this control source generates a
value of +1 when the Pitch Wheel is pulled fully down.
38
Global ASR (GASR2)
When the Globals parameter on the COMMON page is turned on, ASR2 becomes
global, and is labeled GASR2. The functions of ASRs are explained in Chapter 6 in
the Performance Guide , in the section ÒThe ASR Page.Ó This control source does not
appear in the Control Source list for parameters whose functions are local.
39
Global FUN2 (GFUN2)
When the Globals parameter on the COMMON page is turned on, FUN2 becomes
global, and is labeled GFUN2. The functions of FUNs are explained in Chapter 16
in the Performance Guide . This control source does not appear in the Control Source
list for parameters whose functions are local.
40
Global LFO (GLFO2)
When the Globals parameter on the COMMON page is turned on, LFO2 becomes
global, and is labeled GLFO2. The functions of LFOs are explained in Chapter 6 in
the Performance Guide , in the section ÒTHE LFO PAGE.Ó This control source does
not appear in the Control Source list for parameters whose functions are local.
41
Global LFO Phase (GLFO2ph)
When the Globals parameter on the COMMON page is turned on, LFO2 becomes
global, and is labeled GLFO2. The functions of LFOs are explained in Chapter 6 in
the Performance Guide , in the section ÒTHE LFO PAGE.Ó This control source does
not appear in the Control Source list for parameters whose functions are local.
Control Sources
Descriptions of Control sources
25-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K2vxK2vxrK2500rs

Table of Contents