Omron SYSMAC CJ - REFERENCE MANUAL 01-2008 Reference Manual page 1262

Sysmac cs/cj/one nsj series programmable controllers
Table of Contents

Advertisement

Text String Processing Instructions
Variations
Applicable Program Areas
Operands
Note
Operand Specifications
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation
Immediate Refreshing Specification
Block program areas
OK
OK
S: First Source Word
S + maximum 2,047 words
D: First Destination Word
D + maximum 2,047 words
1. The data from S to S +the maximum 2,047 words and from D to D + the
maximum 2,047 words must be in the same area.
2. The data from S to S + the maximum 2,047 words and from D to D + the
maximum 2,047 words can overlap.
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
EM Area without bank
EM Area with bank
Indirect DM/EM
addresses in binary
Indirect DM/EM
addresses in BCD
Constants
Data Registers
Step program areas
Subroutines
OK
15
S
Text string data: 4,095 characters max. + NUL
to
15
D
Text string data: 4,095 characters max. + NUL
to
S
CIO 0000 to CIO 6143
W000 to W511
H000 to H511
A000 to A447
A448 to A959
T0000 to T4095
C0000 to C4095
D00000 to D32767
E00000 to E32767
En_00000 to En_32767
(n = 0 to C)
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
---
---
Section 3-33
MOV$(664)
@MOV$(664)
Not supported
Not supported
Interrupt tasks
OK
0
0
D
A448 to A959
1223

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents