Clock Instructions
Operand Specifications
D and D+1: Result Data
D and D+1 contain the result data in seconds-only format. D and D+1 must be
in the same data area.
15
D
15
D+1
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
EM Area without bank
EM Area with bank
Indirect DM/EM
addresses in binary
Indirect DM/EM
addresses in BCD
Constants
Data Registers
Index Registers
Indirect addressing
using Index Registers
Rightmost 4 digits
Seconds: 0000 to 9999 (BCD)
Leftmost 4 digits
Seconds: 0000 to 3599 (BCD)
S
CIO 0000 to CIO 6142
W000 to W510
H000 to H510
A000 to A958
T0000 to T4094
C0000 to C4094
D00000 to D32766
E00000 to E32766
En_00000 to En_32766
(n = 0 to C)
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
Specified values only
---
---
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
Section 3-28
0
0
D
A448 to A958
---
1131