Omron SYSMAC CJ - REFERENCE MANUAL 01-2008 Reference Manual page 1019

Sysmac cs/cj/one nsj series programmable controllers
Table of Contents

Advertisement

Serial Communications Instructions
980
Name
Communications Port Error
Flag
Communications Port Com-
pletion Codes
Communications Responses
Code
1106 (hex)
2201 (hex)
2202 (hex)
2401 (hex)
Others
Address
A21900 to
ON when an error occurs in network
A21907
communications.
Bits 00 to 07 correspond to logical ports
0 to 7, respectively.
Flag status will be maintained until the
next network communications start.
The flag will turn OFF when communi-
cations start again even if an error
occurred for the last execution.
A203 to A210 Contains the completion code stored
when network communications are per-
formed.
Words A203 to A210 correspond to log-
ical ports 0 to 7, respectively.
The completion code will be 00 while
the communications instruction is being
executed. The new response code will
be stored when execution has been
completed.
The contents of these words is cleared
when operation is started.
Contents
No corresponding program number
Specified Send/Receive Sequence No. that has not
been registered.
Modify the Send/Receive Sequence No. or add the
number using the CX-Programmer.
Not operable due to protocol execution
Since one protocol macro has already been executed,
no further execution is accepted.
Add NC condition to program for the Protocol Macro
Execution Flag.
Not operable due to stoppage
Since the protocol is being switched, no further execu-
tion is accepted.
Add NC condition to program for the Serial Setting
Change Flag.
No registration table
An error has occurred in the protocol macro data or
data is being transmitted.
Transmit the protocol macro data using the CX-Pro-
grammer.
Refer to the CS/CJ-series Communications Commands
Reference Manual (W342) for other response codes.