Overview of User Interface
Menu
Submenu/
Command
Execution,
Find
continued
Convert Ladder to
Mnemonics per
LCU/LCB
Cross-Reference
Connection Map
Show Memory Map
PLC Operating Mode
(applicable only when
CX-Server is used as
the communications
driver)
Change LC Type
Window
Cascade
Tile Horizontally
Arrange Icons
Close
Close All
Recent windows
Block
Searches for registered function blocks with the block
Number
number that has been specified, and moves the cursor to
the function block with the matching block number in the
Project Workspace.
Monitor
Searches for the Monitor Software tag name that has been
Tag
specified, moves the cursor to the function block with the
matching monitor tag in the Project Workspace.
CSV Tag
Searches for the tag name for SCADA software that has
been specified, and moves the cursor to the function block
with the matching CSV tag (tag for SCADA software) in
the Project Workspace.
User Link
Finds the tag name for the user link table related to a
Table
selected field terminal.
Converts all the ladder diagrams in the Loop Controller
into mnemonics.
Displays the cross-references of the selected step ladder
program, i.e., what instructions use contact ITEMs.
Displays the relationship between inputs and outputs for
the selected function block
The status showing how the Loop Controller is using CPU
Unit memory can be displayed as a list.
Changes the operating mode of the CPU Unit from the
CX-Process Tool.
Converts the selected Loop Controller type,
number-model, and unit version when inserting an
LCU/LCB element.
Overlaps and displays windows.
Displays windows side by side.
Aligns icons.
All
Closes all open windows.
Block
Closes all open block diagram windows.
Diagram
Ladder
Closes all open ladder diagram windows.
Diagram
Se-
Closes all open sequence table windows.
quence
Table
Cross-
Closes all open cross-reference windows.
Refer-
ence
Connec-
Closes all open connection map windows.
tion Map
User Link
Closes all open user link table windows.
Table
Closes all open windows.
Displays up to the nine windows most recently used.
Description
Section
2-2
Conditions for
selection
When a Loop
Controller is
selected
When a Loop
Controller is
selected
When a Loop
Controller, node
function block file,
or Project
Workspace is
selected
When a field
terminal is selected
When an LCU or
LCB element is
selected
When an LCU or
LCB element is
selected
When function block
file for a node is
selected
When an LCU or
LCB element is
selected
When a function
block file, LCU/LCB
element, function
block group, or
function block file is
selected
When an LCB
element is selected
---
---
79

Advertisement