Available commands are listed below.
S
Set whether the power supply is enabled or disabled.
Press "S." The command prompt changes to "Select port number to be
changed>." Enter the port number for which you wish to change the setting.
Press "0" to change the settings of all ports at a time. Then, the command
prompt changes to "Up or Down PoE port admin status (U/D)>." Press "U" to
enable power supply (Up). Press "D" to disable it (Down). When you complete
the setting change, the display on the screen is automatically updated.
I
Set the power supply priority.
Press "I." The command prompt changes to "Select port number to be
changed>." Enter the port number for which you wish to change the setting.
Press "0" to change the settings of all ports at a time. Then, the command
prompt changes to "Enter the selection >." Press "1" for "Critical." Press "2" for
"High." Press "3" for "Low." When you complete the setting change, the display
on the screen is automatically updated.
L
Set the upper limit of supplied power.
Press "L." The command prompt changes to "Select port number to be
changed>." Enter the port number for which you wish to change the setting.
Press "0" to change the settings of all ports at a time. Then, the command
prompt changes to "Enter the power limit>." Enter the limit between 3000 and
15400 mW (in units of 200 mW). When you complete the setting change, the
display on the screen is automatically updated.
Q
Return to the previous menu.