Removing FEP
tubes: → p. 142
The cleaning valve
(3) is just labelled
in this illustration to
identify it for preventive
maintenance and is not
part of the procedure.
196
Repair > Milk Module Repairs (Metal Component Support)
11.14.11 Replace Steam Heating Chamber
C
A
3
Prerequisites
• Steam valve is removed → p. 195.
Procedure
1. Remove the FEP tubes (A+B) on both sides of the steam heating chamber (2).
2. Loosen 2 screws (crosshead, circled in red) from the steam heating chamber (2).
3. Pull the steam heating chamber (2) out of the holding plate (1) together with the
FEP tube (C).
Momento 120 Service Manual
B
1
2
Fig. 168
Version 1.4 EN