6.4.3 Milk Pump Calibration

milk pump calibration
please place a measuring cup under the outlet
1. Place a measuring cup under the
outlet that holds at least 150 ml and
tap on the "confirm" symbol.
milk pump calibration
117 ml
dispensed volume
3. Enter the dispensed volume and tap
on the "confirm" symbol.
milk pump calibration
109 ml
dispensed volume
5. Repeat the procedure two more
times.
Please note that the dispensed volume is not adjusted during the pro-
cedure. The calibration is done by calculating the average of the three
entered shot volumes.
To ensure that the calibration was successful, dispense a test product.
Version 1.4 EN
2. Wait until the milk shot is dispensed.
please enter
empty measuring cup and place it again under the outlet
dispensed volume
4. Empty the measuring cup, put it
back under the outlet and tap on the
"confirm" symbol.
please enter
dispensed volume
6. Tap on the "confirm" symbol on the
final screen.
MMI Menus > Technician Menu
milk pump calibration
milk pump calibration
milk pump calibration
calibration completed successfully