11.14.12 Replace Milk Pump
1
A
2
Prerequisites
• Air valve is removed → p. 187.
• Boiler is removed → p. 193.
• Steam valve is removed → p. 195.
Procedure
1. Remove the FEP tube (A) from the suction nozzle valve (1).
2. Remove the FEP tube (B) from the steam heating chamber (2).
3. Unplug the connector (circled in red, see detail) from the pump (4).
4. Loosen 2 screws (crosshead) on the holding plate (3) to release the milk pump (4).
5. Pull the milk pump (4) out of the holding plate (3).
Version 1.4 EN
Repair > Milk Module Repairs (Metal Component Support)
B
Momento 120 Service Manual
Removing FEP
tubes: → p. 142
4
3
Fig. 169
197