11.11.2 Remove Head Base Plate
Prerequisites
• Main PCB cover is removed → p. 109.
Procedure
1. Pull out the connector clip (2) from the hose adapter (3) with pointed pliers.
2. Pull off the hose (4) with hose adapter (3) from the valve (1).
3. Replace the O-ring (5) seated between valve (1) and hose adapter (3).
Version 1.4 EN
Repair > Coffee Module Repairs
1
2
3
4
Momento 120 Service Manual
Danger of
damage! Always
replace the O-ring
when pulling off a hose
adapter from a valve.
5
Fig. 69
111