3. Cut the cable ties (a) with side cutting pliers.
4. Remove the cable tie (b) by pressing it together with pliers and then pull it out of
the hydraulic components support, but do not cut it.
5. Remove the tube (A) from the pressure sensor (1).
6. Unplug the two connectors (c+d) from the magnetic valve (2).
7. Unplug the connector (e) from the pressure sensor (1).
8. Unplug the air valve electronics connector (f).
9. Unplug the connectors (g+h) from the steam valve (3).
10. Unplug the connector (i) from the milk pump (4).
Version 1.4 EN
Repair > Milk Module Repairs (Plastic Component Support)
Momento 120 Service Manual
Removing FEP
tubes: → p. 142
Fig. 143
173