11.10.6 Remove Drip Tray Contacts for Cleaning
1
Prerequisites
• Milk module is removed → p. 90.
Procedure
1. Loosen 1 screw (TX20) on drip tray contact plate (3).
2. Turn the drip tray contact plate (3) around and clean the contacts (see detail,
yellow surfaces).
3. Also clean the contacts (1) on the drip tray (2) itself (see detail, yellow surfaces).
Version 1.4 EN
Repair > Chassis Repairs
2
3
Momento 120 Service Manual
This procedure only
needs to be done
if the drip tray is not or
not always recognised
when placed onto the
machine.
Fig. 60
103