Removing FEP
tubes: → p. 142
168
Repair > Milk Module Repairs (Plastic Component Support)
11.13.7 Replace ntC Fluid line
A
This component and connected pipes are under pressure (→ p. 15),
follow the instructions on page 140 in advance!
Prerequisites
• Emptying valve is removed → p. 167.
Procedure
1. Remove the FEP tube (A) from the steam heating chamber (2).
2. Unclip and pull up the security valve (3) to get access to the NTC connector(a).
3. Unplug the connector (a, circled in red) of the NTC (1).
4
4. Pull out the tube (B) from the boiler (4) in the same way as FEP tubes.
5. Pull the NTC assembly (5) out far enough to be able to remove the FEP tube (C).
6. Remove the NTC assembly (5) together with its connector (a).
Momento 120 Service Manual
1
2
B
5
C
3
a
Version 1.4 EN
Fig. 137
Fig. 138