Nespresso Momento 120 Service Manual page 126

Coffee/milk machine
Hide thumbs Also See for Momento 120:
Table of Contents

Advertisement

126
Repair > Coffee Module Repairs
8. Unscrew 2 flat receptacles of the ground wire from thermoblock (2) on the power
supply (2).
9. Release the flat receptacle of the ground wire at the power supply (1).
This kind of flat receptacle has a special connector latching.
Press down the lever with flat nose pliers while pulling on it.
10. Pull the wires out of the guides and wire saddles.
11. Lift the thermoblock (2) off of the coffee module.
Assembly tips
• Make sure that the cross beam screws are countered with a square nut.
• Only use the black coloured connector clips for the hose adapters which connect
directly to the thermoblock (2).
• Always replace the O-ring seated between the thermoblock (2) and hose
adapters.
Momento 120 Service Manual
1
2
Fig. 85 
Version 1.4 EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents